KOREC Direct offers a wide range of inspection tools, such as Avongard Tell Tales for crack width guage to monitor and investigate, Wall Cavity inspection (Endoscope / Boroscopes) and Covermeters to locate wall ties.
Tell Tales are an effective method for diagnosing the cause of structural cracking is to monitor the movements across a crack for a period of time. The appropriate remedial work can then be specified. Cracks occur in most buildings and civil engineering structures. Monitoring the changes in crack width is an important diagnostic technique for determining the cause and specifying the remedial work. The crack width guage is specifically designed to assist those who survey and report on damaged buildings.
The Interscope is a cavity wall inspection unit for investigating unlit wall cavities up to 1.5m. The portable endoscope is suitable for many different applications for visual inspection of ventilation systems, cabling installations, fabrications, castings, engines and other automotive applications.
The current Kolectric concrete cover meter for rebar detection (locating steel reinforcement bars) is the MC8020 Covermeter which features automatic bar sizing with immediate update, closely spaced bar discrimination techniques using pulse induction. Locating steel reinforcement bars and metal pipes is essential in the construction and maintenance of structures |